°ø±âÃÑ Àü¿ë °í¾Ð°¡½º ·¹±Ö·¹ÀÌÅÍ
Products Feature
°ø±âÃÑ Àü¿ë ·¹±Ö·¹ÀÌÅÍ ½Ã¸®Áî

082½Ã¸®Áî´Â °í¾Ð°¡½º Àü¿ë ·¹±Ö·¹ÀÌÅͷμ­ ¸ðµç °í¾Ð°¡½º¸¦ ¾ÈÀüÇÏ°í Æí¸®ÇÏ°Ô »ç¿ëÇÒ ¼ö ÀÖµµ·Ï °³¹ßµÈ ·¹±Ö·¹ÀÌÅÍ ½Ã¸®Áî ÀÔ´Ï´Ù, ƯÈ÷ °í¾Ð¿ë °ø±âÃÑ ÃæÀü Àü¿ë NPT 1/4" type Á¦Ç°À̸ç, ³»ºÎÀÇ ¸ðµç ºÎǰÀº Stainless steel 316L·Î ÀÌ·ç¾îÁ®ÀÖ½À´Ï´Ù. ÀÔ±¸ ¾Ð·ÂÀº ÃÖ´ë 6000psig(420bar) Á¶Àý(¼ÂÆÃ)¾Ð·ÂÀº ÃÖ´ë 4500psig(310bar)±îÁö »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.

¶ÇÇÑ ¿ÜºÎÀûÀÎ Áøµ¿°ú °¡½º¶óÀÎÀÇ ¹Ì¼¼ Áøµ¿ µîÀ¸·Î ÀÎÇÏ¿© ÃÊ±â ¼ÂÆÃ °ªÀÌ ¹Ì¼¼ÇÏ°Ô Á¶±Ý¾¿ º¯ÇÏ´Â Çö»óÀ» ¿ÏÀüÈ÷ ÇØ°áÇÑ µå¶ó½ºÅ¸ ¸¸ÀÇ Push and Lock ŸÀÔ(ƯÇã 1086199Ãâ¿ø)ÀÇ Á¶Àý ¼ÕÀâÀ̸¦ Àû¿ëÇÏ¿© »ç¿ëÇϱ⿡ ´õ¿í Æí¸®ÇÕ´Ï´Ù. Á¶Àý ¼ÕÀâÀ̸¦ ´©¸£¸é ¼ÂÆÃ°ªÀÌ º¯ÇÏ´Â °ÍÀ» ¿ÏÀüÈ÷ ¹æÁöÇϸç, ¼ÕÀâÀ̸¦ ¾ÕÀ¸·Î ´ç±â¸é ÀÚÀ¯·Ó°Ô ¿øÇÏ´Â ¾Ð·ÂÀ¸·Î ´Ù½Ã ¼ÂÆÃ ÇÒ ¼ö ÀÖ´Â µå¶ó½ºÅ¸ ¸¸ÀÇ Æ¯Çã Ãâ¿øÇÑ Push and Lock ŸÀÔÀÇ ·¹±Ö·¹ÀÌÅÍ ÀÔ´Ï´Ù.
Ordering Information.
082 B -      4500 -     1S
BASIC SERIES NUMBER BODY MATERIAL OUTLET PRESSURE RANGE FLOW CAPACITY
Standard
Inlet Pressure 6000psig(420bar)
B = Brass
S = STS 316L

3000 = 3000psi (20-210bar)
4500 = 4500psi (30-310bar)

1 = 1/4" Female NPT
1S = Cv 0.06 Standard
Specification

 Ports

1/4" Female NPT
082 Series Only 4-Ports

 Leak Rate Certification

 to 2 x 10-8 atm cc/sec Helium available.

 Body Materials

082S-4500-1S  Stainless steel 316L
082B-4500-1S  Nickel Plated Brass

 Bonnet Material

 Nickel Plated Brass (Stainless steel 316L Optional)

 Diaphragm

082S-4500-1S  Stainless steel 316L
082S-4500-1SH  Hastelloy-C Optional

 Main Valve

Stainless steel 316L

 Valve Spring

Stainless steel 316L

 Valve Seat

Teflon (Kel-F, Polyimide, etc.. Optional)

 Inlet Pressure Ranges

082x-3000-1S 3000psi (210bar)
082x-4500-1S 4500psi (310bar)

 Outlet Pressure Ranges

082x-3000-1S 3000psi (210bar) 082x-4500-1S 4500psi (310bar)

 Operating Temperature

-40¡ÆC ~ +70¡ÆC (-40¡ÆF ~ +165¡ÆF) Standard
082S-4500-xx-H1 +120¡ÆC Optional
082S-4500-xx-H2 +250¡ÆC Optional
+250¡ÆC ~ +540¡ÆC (+328¡ÆF ~ +1000¡ÆF) Optional

 Flow Capacity

082x-4500-1S Cv=0.06 Standard
082x-4500-1O Cv=0.2 Optional

 Standard Optional

Inlet CGA, Outlet etc..
Technology & Certification
°¢ Á¦Ç°µéÀº ÃÖ°íÀÇ ¾ÈÀü¼º°ú ½¬¿î Á¶ÀÛ¼ºÀ» °í·ÁÇÏ¿© Á¦À۵Ǿú½À´Ï´Ù. ±×·¯³ª °¡Àå ¾ÈÀüÇϰí È¿À²ÀûÀÎ Regulator »ç¿ëÀ» À§Çؼ­´Â ½ÇÁ¦ »ç¿ë ¾Ð·ÂÀ» °¢°¢ ¸ðµ¨ÀÇ »ç¿ë ¾Ð·Â¿¡ 25% ~ 75% À̳»¿¡¼­ »ç¿ëÇÏ¸é °¡Àå ÀÌ»óÀûÀÎ ¾Ð·ÂÀ» »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù, Á¤¹ÐÇÏ°í ¿øÈ°ÇÑ µ¿ÀÛ°ú Á¦Ç°ÀÇ ¼ö¸í ¿¬ÀåÀ» À§Çؼ­´Â ¸ðµ¨¿¡ µû¶ó 10bar<145psi> ~ 250bar<3600psi>¹üÀ§ ³»¿¡¼­ »ç¿ëÇϱ⸦ Àû±Ø ±ÇÀåÇÕ´Ï´Ù.
Sales information
¼­¿ï½Ã ±¸·Î±¸ ±¸·Î3µ¿ 222-31 ÁöÇ÷¯½º 202È£(±¸·Îµ¿ µðÁöÅзΠ26-123)
Tel : 02-2637-0114 Fax : 02-2637-3114
E-mail : dragon@drastar.com